Open Circuit Test and Short Circuit Test on Transformer| Electrical machines|Ch 7
Автор: Read Electric Vehicle
Загружено: 2025-08-14
Просмотров: 110
Описание:
Open circuit test and short circiut test on transformer are called non loading test.
Open circuit test is called no load test
1. high voltage side is open
2. measurements are done in low voltage side.
From no load test, we can find
No load current
Core losses
Equivalent circuit parameters
Core loss resistance
Magnetizing reactance
Short circuit test
LV side is shorted
Copper losses at full load
Equivalent circuit parameters
Resistance
Leakage Reactance
-------------------------------------------------------------------------------------------------------------