Concrete Batching Controller Calibration BP RP Value & Boom Sensor Setting
Автор: Manoj Flori Guru
Загружено: 2025-08-29
Просмотров: 208
Описание:
🎥 In This Video we Have Explained Step by Step How to Calibrate a CBC Meter
If You are Operating a Self Loading Concrete Mixer or Batching Controller This Guide will be Very Useful for You
⏱️ Video Timeline
0:00 ✅ Level the machine and clean the bucket
0:25 ⚙️ Go to Setting → Touch Assistance → Enter Password (7249)
1:00 🔍 Diagnostics → Check BP / RP Values
• Boom Angle Sensor ➝ -5000 Down / +5000 (Up)
• BP Value ➝ 17000\18000 Down / reverse (Up)
2:10 🛠️ Calibration Start
• Boom Angle Sensor ➝ 60° (Bucket Down) → Enter
• Proxymatic Calibration → Auto Back
3:00 ⚖️ Machine Tilt → Between 0–4 → Enter
3:35 🔄 1/3 – 2/3 – 3/3 Process (Full RPM \~2021)
4:20 🏗️ Load 8 Cement Bags (Approx. 400 KG)
• Simply Weight → Enter Actual KG (400) and Confirm
5:10 📊 Flat & Ground → Confirm Calibration
5:40 ⚡ At \~50° Machine Angle → Perform Fast Feeding
6:15 🎯 Calibration Complete