|Maximum Distance Between Two Columns|Column &Beam Size with steel details for G1,G2, G3, G4
Автор: Bulid & Boom
Загружено: 2023-02-14
Просмотров: 100
Описание:
What is the minimum and maximum center to center distance between the two columns in RCC building?
What is the minimum and maximum center to center distance between the two columns in RCC building?
Center to center distance between columns is the measurement of length between two columns in building. Columns are the vertical components in the building structure which is used to support the slab section for the building model. The column sections related to the rectangular, square, circular or polygon sections are basically used in RCC structure design. As per the structural design considerations square column sections are having more advantage than rectangular, circular or polygon section because the loading distribution will be same in case of square columns than other sections. In this article I will explain you what are the factors that are effects the center to center distance between the RCC column sections. And what is the minimum center to center distance, maximum center to center distance between two column sections.
The distance between the two RCC column sections depends upon the following factos.
Loading on the structure
Architectural specifications
Use of the building
Height of the building
1. Loading on the structure
Basically loads are classified in to gravity loads and lateral loading conditions. The loading condition which is applied through the gravitational force is come under gravity loading and the loading condition which comes perpendicular to the gravity loading is comes under the lateral loading condition.
Under the gravity loading conditions the loads related to the dead load, live load and floor loads are considered and the loads related to the seismic load and wind loads are comes under the lateral loading condition case.
Due to the effect of the gravity loading effect like dead load, live load and floor loads in the building structure the deflection is occurred in vertical direction. And due to lateral loading conditions
like seismic loading effect and wind loading effect the defection of the building will occur in the horizontal case through length and the width of the building structure.
If the loading condition is high on the building the less values of center to center distance is considered, and if the loading condition is less than the higher values of center to center distance considered for basic RCC building structures.
2. Architectural specifications
The center to center distance between RCC column sections is also depends upon the architectural plan and specifications of the building structure. Depending upon the requirements of the customer or client the distance between the two column sections increases or decreases.
If the client is required high center to center distance between the column section the depth of the beam section increases for the building in order to resist the total loading condition on the building structure. At the same time it effects on the cross section of the column in the building structure.
The complete concepts of depth and width of the beam section is explained in my precious article please click here to see.
3. Use of the building
There are the different types of the related to the residential buildings, educational buildings, institutional buildings, assembly buildings, business buildings, mercantile buildings, industrial buildings and storage buildings. Depends upon building type considerations the number of columns and center to center distance between RCC column sections increases or decreases.
For the industrial buildings, assembly buildings and storage buildings the center to center distance is assumed as high values when we compared with other type of structures like residential, business buildings etc.
4. Height of the building
The height of the building structure is the last and fourth factor we will consider in building design. If the building height is increases the total loading on the building also increases due to that reason the distance between two columns are decreases. But for specific buildings under specified conditions this factor will not effects the center to center distance.
What is the center to center distance between two RCC columns? What is the distance between RCC columns?
The distance between the two RCC column sections is classified in to three types.
Normal condition distance
Minimum distance
Maximum distance
Normal condition center to distance
For normal building structure the regular center to center distance between two column sections are considered as 12’0” to 16’0” distance, which is approximately 3m to 5m distance under normal condition.
Minimum center to distance
The minimum distance is the least value of center to center distance considered in building design. For the building structures the minimum value is taken as approximately 8’0” distance, which is approximately 2.5m as the least value in design of building.