Split AC outdoor condenser change | how to change aluminium condenser into copper condenser
Автор: ROYAL AC SOLUTION
Загружено: 2023-06-08
Просмотров: 1699
Описание:
how to change aluminium condenser in split Ac
1. Safety precautions: Ensure that the power supply to the condenser is turned off. This will prevent any electrical accidents during the replacement process.
2. Locate the condenser: The condenser is typically situated outside your building, attached to the exterior wall or placed on a concrete pad. It looks like a large metal box with fins on the sides and a fan on top.
3. Disconnect the power: Locate the electrical disconnect switch or circuit breaker that controls the condenser unit. Flip the switch or turn off the breaker to cut off power to the condenser.
4. Release the refrigerant: To comply with environmental regulations, it's important to have a licensed professional evacuate the refrigerant from the system. This step requires specialized equipment and expertise. Contact a qualified HVAC technician to handle this part of the process.
5. Remove the panel: Unscrew or unclip the access panel on the condenser. This will expose the internal components.
6. Disconnect the wiring: Take note of the wiring connections and their positions. Carefully disconnect the electrical wires attached to the condenser. You may need to use a screwdriver or pliers, depending on the type of connectors.
7. Remove the refrigerant lines: Identify the refrigerant lines connecting the condenser to the air conditioning or refrigeration system. Use an adjustable wrench or appropriate tools to disconnect the lines. Make sure to catch any residual refrigerant that may escape during this step.
8. Detach the condenser unit: Depending on the specific installation, the condenser may be secured by bolts, brackets, or straps. Remove these fasteners and carefully lift the condenser unit away from its mounting.
9. Install the new condenser: Position the new aluminum condenser in the same location where the old one was located. Make sure it is level and properly aligned. Secure it using the appropriate fasteners.
10. Reconnect refrigerant lines: Attach the refrigerant lines to the corresponding connections on the new condenser. Tighten the fittings using appropriate tools, ensuring they are properly sealed.
11. Reconnect electrical wiring: Refer to the notes you took during the disconnection process and reconnect the electrical wires to their respective terminals on the new condenser.
12. Replace the access panel: Secure the access panel back onto the condenser and tighten the screws or clips to ensure it is firmly in place.
13. Restore power: Go back to the electrical disconnect switch or circuit breaker and turn it on to restore power to the condenser.
14. Test the system: Switch on your air conditioning or refrigeration system to verify that the new condenser is functioning correctly. Monitor it for a while to ensure everything is working properly.
Please note that it is recommended to hire a licensed HVAC technician for the refrigerant evacuation and charging process, as working with refrigerants requires specialized knowledge and equipment.