HTP: Fault Code FLU: HI FLUE PRESS FLU: This display indicates that there is excessive flue pressure. This code will reset automatically after the high pressure condition is resolved. The second line indicates the status of the pump.
1. Assure that the flue is not blocked.
2. Check the switch wiring by applying a jumper in place of the switch. If the code clears with the jumper in place, REPLACE the flue switch and connect the wires to the new switch BEFORE running unit.
Do not use a jumper to remedy this error. A faulty switch MUST be replaced. Failure to do so could result in serious injury or death.