Veichi SI23 & SI30 First Set-up (Solar Pumping Application)
Автор: Cedar Solar
Загружено: 2024-04-10
Просмотров: 6607
Описание:
THE FIVE SETTINGS REQUIRED FOR A BASIC SI23 SETUP
Main Menu: F00 sub-menu: F00.12 is low-speed cut-off frequency Hz
Main Menu: F05 sub-menu: F05.02 is motor size selection kW
Main Menu: F05 sub-menu: F05.04 is operational speed RPM
Main Menu: F05 sub-menu: F05.06 is amps for motor A
Main Menu: F14 sub-menu: F14.14 is low speed protection detection frequency Hz
(Example is 1.1kW - use your AC pump specs and change accordingly). SI30 uses same settings but an external programming keypad needs to be plugged into the unit to program it.
www.cedarsolar.com