After checking the setup as outlined above, power up the IDU as follows:
• Connect DC output from the power supply to the +24 VDC input of the IDU.
• Connect the AC cord to the external power supply, and then plug the AC power
cord into the AC outlet.
Upon boot up, the PWR LED illuminates green, and within several seconds the STATUS
LED flashes green as the unit performs a self-diagnostic test. If this test is successful,
the STATUS LED illuminates green. If the test fails, the STATUS LED illuminates red.
After the initial hardware diagnostic, the system takes approximately one minute to
complete the boot up cycle, during which the STATUS LED flashes green. If the
application successfully loads, the STATUS LED illuminates solid green. If the
application cannot start due to configuration or other errors, the STATUS LED
Monitoring LED Status Indicators
Once the IDU is powered up with the appropriate Options file, check the LEDs to
ensure the IDU is functioning properly.
Front Panel Power and Network LED Status Indicators
For diagnostic purposes, the IDU chassis has five LED indicators located on the front
panel.
• The PWR LED indicates whether the IDU is powered on or off.
• The STATUS LED indicates the IDU overall status.
• The NET LED indicates the IDU network acquisition status.
• The Tx LED indicates the IDU transmitter status.
• The Rx LED indicates the IDU receiver status
iDirect 3000 series™ Satellite Router Installation and Safety Manual
The colors of the LEDs indicate the state of the IDU as defined in Table Table 15 Front Panel LED Indicators
LED Label LED Color Indicated Unit Status
PWR
OFF Indicates that the IDU is powered off or
there is a Power Supply problem.
GREEN Indicates that the IDU is powered on. The
bootloader has started.
NET
GREEN Indicates that the remotes have been
acquired into the network.
FLASHING GREEN Indicates that the elements are in network
acquisition.
YELLOW Indicates that the downstream SCPC is
locked.
FLASHING YELLOW Indicates that the downstream SCPC is not
locked.
STATUS
GREEN IDU is functioning properly. The DRAM test
is successful.
FLASHING GREEN Indicates that the unit is booting. The
DRAM test is in progress.
RED Indicates a serious fault or failure in
software, hardware, or configuration. May
indicate that the DRAM test failed.
TX
GREEN Indicates that the IDU transmitter is
enabled.
YELLOW Indicates that the IDU transmitter is
disabled.
RX
GREEN Indicates that the receiver is successfully
locked to the downstream.
YELLOW Indicates that the IDU is not locked to the
downstream carrier.