How to check EEV COIL/MOTOR with a multimeter Error code e416
Автор: Taddy Digest
Загружено: 2020-01-14
Просмотров: 32259
Описание:
Error Code E416 is compressor stop - high discharge temperature.
EEV Wires should be checked at plug CN403 from blue your common to all other wires.
Ohms should read 46.
Hope this helps you diagnose properly.