How to Use In. Licht to Measure Light Correctly
Автор: Lighting Recipe Studio
Загружено: 2026-01-25
Просмотров: 11
Описание:
Accurate lighting design begins with accurate measurement — and that starts with correct device positioning.
In this demonstration, we show how the In. Licht series supports three key lighting measurement applications:
✅ 1. Measuring Light Source Quality
🔹 Use In. Licht Ultra to verify the performance of a light source.
🔹 Position Ultra directly in front of the light source
🔹 Distance: 10–50 cm
🔹 Sensor facing the source
🔹 This ensures reliable evaluation of spectral and source-level quality.
✅ 2. Measuring Ambient / Task Lighting
🔹 To measure horizontal illuminance for work surfaces: Use In. Licht Pro / Ultra / Well
🔹 Place devices flat on the table
🔹 Sensor facing upward
🔹 This is ideal for desks, tables, and general task lighting assessment.
✅ 3. Human-Centric Lighting Measurement
🔹To capture the light that actually reaches the eyes: Place In. Licht Pro / Ultra at eye level, facing outward
🔹Or mount In. Licht Ultra on a tripod: 45 cm above the table | 140 cm above the floor
🔹For continuous monitoring: Mount In. Licht Well on the wall at 140 cm height, Sensor facing the room
Measure correctly. Design better light.
In. Licht helps lighting professionals move beyond assumptions — toward measurable, verifiable lighting outcomes.
➡️ In. Licht Pro
🔹Circadian reference modes: Morning | Daytime | Evening | Deep Sleep
🔹Activity-based presets: Reading, Working, Meditation, Education, Meetings, Relax, Greeting
🔹Simplified uniformity control: Lux, CCT, contrast balance
🔹Continuous monitoring with smart system integration
➡️ In. Licht Ultra
🔹Core photometric & color metrics: Illuminance, CCT, CRI, CIE x/y, Duv, TM-30, Spectrum, SDCM
🔹Human-centric metrics: EML, m-EDI, CAF, S/P Ratio, Circadian Stimulus, Blue Light Hazard
🔹Flicker risk analysis: Percent Flicker, Flicker Index, Frequency, SVM
🔹Step-Shot & spectrum comparison with multi-point capture and CSV export
➡️ In. Licht Well
🔹General lighting: Illuminance, CCT, SDCM, Duv
🔹Human-centric metrics: EML, m-EDI
🔹Flicker risk: Percent Flicker, Flicker Index, Frequency, PstLM, SVM
🔹Air quality: PM2.5, PM10, CO₂, TVOCs, HCHO
🔹Thermal comfort: Temperature, Relative Humidity
🛒 Shop In. Licht
US: https://www.amazon.com/stores/InLicht...
Germany: https://www.amazon.de/stores/InLicht/...
UK: https://www.amazon.co.uk/stores/InLic...
Other regions: https://lightingrecipe.com/where-to-buy/
Authorized Distributors
US: LEDmetric
Singapore: Schideron Technologies APAC Pte Ltd
India: Lumen Optiks Private Limited
#InLicht #LightingMeasurement #HumanCentricLighting #WELLBuilding #LightingDesign #ArchitecturalLighting