CMTD42M-F : Troubleshooting and Maintenance Video | Compact Module Thermodynamic Trap Full Version
Автор: Forbes Marshall
Загружено: 2018-03-08
Просмотров: 19868
Описание:
The Forbes Marshall Compact Module Thermodynamic Trap, CMTD42M-F, is a compact thermodynamic trap module designed with an in built bypass valve, a trap vent valve and a trap test valve for steam applications upto 42 bar g. Replaceable trap internals and inbuilt strainer eases inline maintenance. The CMTD42M-F has an integral upstream and downstream piston valve, which isolates the upstream piping of the steam trap.
Installation
Ensure the following for the CMTD42M-F to operate correctly and remove condensate effectively.
1.The CMTD42M-F is installed with flow in the direction of the arrow. Flow to be horizontal.
2.Ensure that there is sufficient access to the hand-wheel to allow proper operation of both upstream and downstream isolation valves.
3.Ensure that there is sufficient access to the strainer to allow it to be cleaned periodically.
4.Allow sufficient access for the bypass valve, trap vent and trap test valve to operate.
5.Ensure all the valves are either full opened or tightly shut, and never kept partially open / crack open.
After 24 hours in service the cover nuts should be checked for tightness. Separate user manual which comes along with the product gives full details