MOVIDRIVE B Training Session 6 - Lab 6 - Ramps and Acceleration
Автор: SEWEurodriveUSA
Загружено: 2021-01-28
Просмотров: 9725
Описание:
The sixth lab discusses how the ramp time parameters of the MOVIDRIVE® need to be calculated from the desired real time acceleration you want the motor to have. We prove the results by using a timer to show this functionality. We also demonstrate how to activate an alternate ramp time using an input assigned to be a ramp changeover. We conclude this lab by demonstrating how the emergency ramp parameter that is used for MOVIDRIVE® fault conditions will also use the same calculation method as the standard ramp time parameters.
For questions or support outside the United States, please visit:
https://www.sew-eurodrive.de/meta-pag...
Lab 6 PDF: https://acrobat.adobe.com/id/urn:aaid...