How to Troubleshoot a Faulty High Pressure Cutout on a Residential AC
Автор: Interplay Learning Interactive Training
Загружено: 2019-04-10
Просмотров: 49639
Описание:
Follow along with Tim Smith as he walks you through the steps to diagnosing a faulty high-pressure cutout switch (HPCO) on a residential A/C.
Is the thermostat calling for cooling?
Which electrical loads are operating?
Is the indoor fan unit operating?
Is the outdoor fan unit operating?
Is the amperage cycling between 0 amps and 30 amps, or staying at 0 amps?
Is 24VAC measured at the contactor?
Visit our website: www.interplaylearning.com
Start a Free Trial of the HVAC Training Program by going to: https://www.interplaylearning.com/diy...
Reach out anytime with questions - [email protected] .
Check out other Interplay videos here:
• Interplay Learning HVAC Team Training
• Residential AC Leak Troubleshooting Video
• House Wiring Basics - Wiring a Residential...
Learn more about Interplay Learning here:
https://www.interplaylearning.com/
We’d love to hear from you! Connect with Interplay Learning here.!
/ interplaylearning
/ interplaylearn
https://twitter.com/i/flow/login?redi...
About Interplay Learning:
Austin-based Interplay Learning is the industry leader in immersive training solutions for the skilled trades. Our award-winning online and VR/simulation-based training for the essential skilled trades enables rapid upskilling and empowers new technicians to be job-ready within weeks, not years. Featuring expert-led videos, hands-on 3D simulations, knowledge checks, and personalized learning paths, our immersive learning platform is more scalable and engaging than traditional training. Leveraging advanced technologies like AI and VR, Interplay is reshaping the future of online skilled trades training, delivering highly effective, always-on learning experiences that result in better careers and better lives.
#INTERPLAYVR #VRLEARNING #INTERPLAYLEARNING