SOP: Sump Pump Discharge Assembly & Airlock Prevention
Objective: To properly assemble the discharge piping for a 1/2 HP effluent sump pump, including size reduction and the installation of an airlock relief hole to ensure reliable pump operation.
Video Reference Map
[00:16] – Installing the 2" to 1.5" PVC Bushing.
[00:29] – Installing the 1.5" Male Adapter.
[00:49] – Drilling the Airlock Relief Hole.
[01:06] – Priming PVC Components.
[01:11] – Applying PVC Cement (Glue).
[01:14] – Final Pipe Insertion and Set.