Fire Safe Implementation of Visible Mass Timber in Tall Buildings - Compartment Fire Test 2
Автор: Mass Timber Fire Research
Загружено: 2021-02-04
Просмотров: 392
Описание:
Reports and information of the project can be found at https://www.ri.se/en/what-we-do/exper...
Main information about this experiment:
Compartment dimensions:
23.0 ft x 22.5 ft x 9.0 ft
(7.0 m x 6.85 m x 2.73 m)
Structural materials:
CLT (ANSI/APA PRG 320, 2018 compliant)
Glued Laminated timber (ANSI A 190.1-2017 compliant)
Exposed surfaces:
100% of CLT Ceiling
100% of Left wall
100% of Right wall
100% of Glulam beam under the ceiling
Other interior surfaces were protected with 3 layers of 5/8" Type X gypsum
Fuel (typical apartment furniture): 560 MJ/m2
Opening factor (based on statistics of apartments): 0.062m^0.5