If you experience false fire alarms, try tuning the flame protection trigger threshold until false alarms no longer occur.
I. Adjust the trigger threshold of the flame sensor to reduce the probability of false triggering of the sensor. The specific operations are as follows.
a). Connect to lightburn and select the appropriate port and baud rate (115200).
b). Send the command "$42" to the console to obtain the current trigger threshold.
c). Send the command "$42=1300" to the console. 1300 is the trigger threshold, the lower the value, the harder it is to trigger. It will be automatically saved after setting. You can send "$42" to read the settings and confirm that the settings are successful.
d). Test whether it is triggered again. If it is triggered again, repeat step c and change the threshold to a smaller value until it is no longer triggered.
II. Turn off the flame sensor function, send the command "$38=0" (if you want to turn it on again, please send the command "$38=1"), and the settings will be automatically saved.