How to re-pack your Glide inflatable waistbelt PFD
Автор: Palm Equipment
Загружено: 2016-03-03
Просмотров: 6567
Описание:
Follow this simple visual guide step by step, to re arm your Glide PFD, and fit it neatly back inside the pouch.
You'll need a re-arming kit, including:
1 x new 24g carbon dioxide cylinder
1 x re-arm Pin
Instructions:
1) Unscrew and remove the empty gas canister, then push the inflation lever back to its original position.
2) Deflate the air chamber by removing the cap from the oral inflation tube, and using it to press in the valve.
3) Squeeze out as much air as you can, starting from the left side, and working your way around towards the valve.
(It may take a couple of attempts to get all the air out)
4) Once deflated, insert a re-arm pin. Screw in a new 24g Co2 canister.
5) Follow the folding instructions printed on the air chamber
6) Insert the chamber back into its pouch, with the gas canister facing the front of the pouch, and the inflation toggle hanging down.
Now you’re ready to go!