LCMS 8060NX - Liquid Chromatograph Mass Spectrometer
Автор: Shimadzu Scientific Instruments
Загружено: 2022-05-05
Просмотров: 215
Описание:
The LCMS-8060NX is a triple quadrupole mass spectrometer with world-class sensitivity and detection speeds. It boasts increased robustness and ease of use as well as Analytical Intelligence to maximize your laboratory’s output.
The Culmination of Shimadzu's Expertise in Triple Quadrupole Mass Spectrometry
-IonFocus™ unit
A newly-developed ESI probe with focus electrodes introduces ions into the mass spectrometer more efficiently, while expelling contaminants to reduce noise and provide more stable data. In addition, an improved heat-assist design promotes the ionization of a wide range of compounds. (Patented technology.)
-UF-Qarray™Ⅱ, UF-Lens™Ⅱ
Re-engineered ion guide improves robustness without compromising on sensitivity. Maintenance of UF-Qarray II and UF-Lens II can be performed easily without tools.
-Easy maintenance interface
The LCMS-8060NX inherits all the ease of maintenance of its predecessors. Both the desolvation line (DL), which introduces the sample into the vacuum, and the ESI capillary can be replaced easily and in a short time. The DL can be replaced while maintaining the vacuum, minimizing downtime.
-Maximized sensitivity, minimized matrix effects
In the newly-developed IonFocus unit, the ion transport electrodes reduce sensitivity loss from matrix effects by expelling neutral matrix particles with greater efficiency. The graphs below show an analysis example of residual pesticides in tea leaves. Using the LCMS-8060NX's world-class polarity reversal speed (5 ms) and data capture speed (1.5 ms), stable data was obtained even for high-speed analysis of multiple components. The IonFocus unit also introduces ions into the detector more efficiently, improving the signal intensity. Of the 100 compounds tested, 96% showed excellent recoveries.
-Superior robustness
The LCMS-8060NX employs new ion guides, the UF-Qarray II and the UF-Lens II, to increase robustness while maintaining high ion transmission efficiency. Improved robustness means higher laboratory throughput as maintenance interval times increase.
The urine metabolite data shown below provides confidence for the analysis of biological matrices. After the analysis of 1000 urine samples, prepared only by dilution with water, the LCMS-8060NX delivers superior data stability without loss of sensitivity.
#LCMS #LCMS8060NX