All about Marine boiler
Автор: Er Saurya Shankar
Загружено: 2021-11-08
Просмотров: 1774
Описание:
#meoclassIVorals #meoclassIV #mmdorals #boilers #boilerblowdown #scumblowdown #boilerwatertest #boilermountings
All about Marine boiler , Covered all topics of Blow Down, Scum Blow down , Bottom Blow down, efficiency of Boiler , Boiler Water test, Flame Failure reason, Why Boiler is Spherical in shape??? Why Boiler is Cylindrical in shape?? What all are boiler mountings?? What are alarms and trips in boiler??
Flame Failure reason:-
1. F.O. inlet v/v to burner in closed position
2. Line filter chocked .
3. Boiler FO supply p/p not running.
4. Solenoid v/v Malfunctioning.
5. flame eye malfunctioning.
6. Air or steam ration not proper.
7. Fd fan flaps malfunctioning.
8. Trip not reset on contactors.
9. main burner atomiser clogged.
10. Pilot burner nozzle clogged.
11. electrode not generating sparks.
Chemicals to add:-
1. for scale---Trisodium Phosphate
2. Oxygen---Sodium sulphide & hydrazine
3. alkalinity:-sodium hydrooxide.
4. caustic cracking:-sodium sulphate or sodium Nitrate.