ycliper

Популярное

Музыка Кино и Анимация Автомобили Животные Спорт Путешествия Игры Юмор

Интересные видео

2025 Сериалы Трейлеры Новости Как сделать Видеоуроки Diy своими руками

Топ запросов

смотреть а4 schoolboy runaway турецкий сериал смотреть мультфильмы эдисон
Скачать

Firefighter Training: How to Take the Engineers Side PLUG (Fire Hydrant)

Автор: Firefighter Ambitions

Загружено: 2019-04-19

Просмотров: 2759

Описание: 🚨FREE PROGRAM: https://courses.firefighterambitions....
🚨🔥BECOME A FIREFIGHTER PROGRAM🔥🚨https://courses.firefighterambitions....
➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖
👨‍👩‍👧‍👦JOIN THE FREE FIREFIGHTER CANDIDATE FACEBOOK GROUP👨‍👩‍👧‍👦
  / members  
➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖➖

Are you pursuing the career of a firefighter?

If you are, there are some interesting facts you need to know.

You will be required to learn and efficiently extend and operate a firefighter hose line (i.e. Taking a plug "4 inch supply hose line")

Taking a plug ( also known as "connecting to a fire hydrant" to secure a water supply)

Firefighters utilize hose lines to separate ourselves, victims, and the victims property from fire and potentially other hazardous substances. Typically hose lines are found on fire engines but they can also be found on fire brush trucks and quints (a blended fire apparatus equipped with fire engine and ladder capabilities)

Throughout the fire academy, you will be repetitively trained in extended several different types of hose lines. We call these skill stations "HOSE LAYS." Each hose lay you will endure in the fire academy will have its own unique deployment procedure and allotted time allowed to complete the evolution (i.e. Taking a plug "4 inch supply hose line," allows 1:15 water to clamp, 3:15 water to truck)

Bottom line is if you're a firefighter or are pursing the career of a firefighter, it is vital you understand how to take a plug.

Here are the steps necessary to become proficient when extending and operating 4 inch supply hose line:

(TAKING A PLUG) 4 INCH SUPPLY HOSE LINE DEPLOYMENT PROCEDURE:

1️⃣Clear left and right then safely step off the engine
2️⃣Pull the pin, grab the hydrant wrench and humat in your right hand, then grab the
supply line with your left hand, shouldering left
3️⃣With the plug on the (engineers side), run 4-6 feet past the hydrant to have enough supply
hose
4️⃣Place humat in front of you securing with both hands, then yell out to the engineer to "GO"
5️⃣Wait until first coupling drops. Listen and look confirming coupling is fully on the ground
6️⃣(For engineers side), grab the hose with your left hand and 360 spin or dosie doe and
throw the hose over the hydrant
7️⃣Place humat out of danger to you then remove the hydrant steamer cap
8️⃣Once the steamer cap is loose enough to remove with your hands, place the hydrant
wrench on the top operating nut of the fire hydrant
9️⃣Finish removing the steamer cap
1️⃣0️⃣Grab and connect the humat to the hydrant
1️⃣1️⃣Adjust hose accordingly to keep from locking in the gutter and creating kinks
1️⃣2️⃣Ensure that the humat valve is closed and the clamp is placed on the hose line by
saying "valve, clamp, and water," then open the hydrant
1️⃣3️⃣Once the hydrant is fully opened, take the hydrant wrench with you and ensure that
there aren’t any kinks in the supply hose line
1️⃣4️⃣Return hydrant wrench back to it’s ready state
1️⃣5️⃣Begin your pull back with the supply hose until the next coupling in the hose line
hits the ground
1️⃣6️⃣Once the coupling is on the ground, face your danger (the engine) and disconnect
the coupling
1️⃣7️⃣Once the coupling is disconnected, throw the remaining excess supply line back on
the engine (preventing trip hazards). Be sure to yell out “HEADACHE” when doing so
1️⃣8️⃣Grab the male end of the coupling and connect it to the intake valve
1️⃣9️⃣Adjust hose accordingly to ensure the hose doesn’t form major kinks or ends up
under the engine
2️⃣0️⃣Ensure the engineer is ready for water, then open the hose clamp
2️⃣1️⃣Leave the hose clamp on the hose line
2️⃣2️⃣Ensure that there is not any kinks in the hose line
2️⃣3️⃣Don SCBA, grab tools, and meet up with your nozzle partner
2️⃣4️⃣Don mask
2️⃣5️⃣Ensure partner has no exposures or bad mask seals
2️⃣6️⃣Assist with hose line management


Follow our guide, train hard, and allow our family here at firefighter ambitions help you and your family reach your goal of becoming a firefighter.

GOOD LUCK FUTURE FIREFIGHTER!


🚒🔥🚒🔥🚒🔥🚒🔥🚒🔥🚒🔥🚒🔥🚒

💻VISIT: https://firefighterambitions.com 💻

🗣CONTACT ME 🗣
📩Email: [email protected]
📩Instagram:   / ffambitions  
📩Facebook:   / ffambitions  


#firefighterambitions #Howtobecomeafirefighter #Firefightertraining

Не удается загрузить Youtube-плеер. Проверьте блокировку Youtube в вашей сети.
Повторяем попытку...
Firefighter Training: How to Take the Engineers Side PLUG (Fire Hydrant)

Поделиться в:

Доступные форматы для скачивания:

Скачать видео

  • Информация по загрузке:

Скачать аудио

Похожие видео

Тест CPAT: Сдайте тест CPAT для пожарных (ПЕРВЫЙ РАЗ)

Тест CPAT: Сдайте тест CPAT для пожарных (ПЕРВЫЙ РАЗ)

Plug Position  Engineer’s Side

Plug Position Engineer’s Side

LDH Forward Lay Hydrant

LDH Forward Lay Hydrant

Firefighter Training: How to Take the Captain's Side PLUG (Fire Hydrant)

Firefighter Training: How to Take the Captain's Side PLUG (Fire Hydrant)

Соединения гидранта

Соединения гидранта

Restoration of an old Fire Hydrant

Restoration of an old Fire Hydrant

captains plug final

captains plug final

Почему Ядерная война уже началась (А вы не заметили)

Почему Ядерная война уже началась (А вы не заметили)

Упражнение 14-1: Открытие пожарного гидранта

Упражнение 14-1: Открытие пожарного гидранта

Firefighter Training: How to Deploy a 150ft-200ft Quick Attack Hose lay (Step-by-Step)

Firefighter Training: How to Deploy a 150ft-200ft Quick Attack Hose lay (Step-by-Step)

Loading Large Diameter Hose

Loading Large Diameter Hose

MBFD Tank to Hydrant Transition

MBFD Tank to Hydrant Transition

Мне 73. Я жалею, что понял это только сейчас.

Мне 73. Я жалею, что понял это только сейчас.

КАК ЗАЩИТИТЬ ЗАМОК ОТ ВСКРЫТИЯ/#инженер +380683803449

КАК ЗАЩИТИТЬ ЗАМОК ОТ ВСКРЫТИЯ/#инженер +380683803449

SFD Humat Valve Operations

SFD Humat Valve Operations

The Plug Hug Fire Hydrant Cleaning System

The Plug Hug Fire Hydrant Cleaning System

Catching a Plug

Catching a Plug

Почему Польша купила тысячу корейских танков вместо Абрамсов и Леопардов?

Почему Польша купила тысячу корейских танков вместо Абрамсов и Леопардов?

Почему 100 лет в электропоездах применяли не самый лучший двигатель? #энерголикбез

Почему 100 лет в электропоездах применяли не самый лучший двигатель? #энерголикбез

Hydrant Painting - September 2018

Hydrant Painting - September 2018

© 2025 ycliper. Все права защищены.



  • Контакты
  • О нас
  • Политика конфиденциальности



Контакты для правообладателей: [email protected]