HOW TO Master Switch Connection Diagram with Two Way Switches 3 phase distribution DB box wiring NS
Автор: NS ELECTRICAL PLUMBING DIY
Загружено: 2025-08-30
Просмотров: 1240
Описание:
HOW TO Master Switch Connection Diagram with Two Way Switches 3 phase distribution DB box wiring NS
3 phase distribution board wiring diagram
3 phase distribution db box wiring diagram, 3 phase distribution board wiring diagram, single phase distribution board wiring diagram, 3 phase distribution board diagram, 3 phase distribution board wiring, 3 phase distribution board wiring uk, 3 phase distribution box, 3 phase wiring diagram, 3 phase house wiring diagram, 3 phase panel board wiring diagram, single phase db box wiring, distribution box wiring, three phase distribution board wiring, single phase distribution board wiring
Three Phase Electrical Wiring Installation in Home - NEC & IECTo perform 3-phase DB (distribution board) wiring, you need to connect the main power supply's three phases (e.g., brown, black, grey), neutral (blue), and earth (green/yellow) to the incoming terminals of a main breaker (like an MCCB) and then feed each outgoing sub-circuit's breaker (MCB/RCBO) from these phases. Each sub-circuit then connects to its respective phase(s), neutral, and earth using appropriate cables and terminal bars.
1. Safety First
Turn off the power: Before starting any work, ensure the main power supply is completely shut off to the distribution board to prevent electric shock.
2. Understand the Components
Distribution Board (DB): This is the central panel that distributes power to smaller circuits.
Main Breaker (e.g., MCCB): A single large circuit breaker that controls the entire incoming power supply to the DB.
Sub-Circuit Breakers (MCBs/RCBOs): Smaller circuit breakers for individual circuits, like lights or sockets.
Terminal Bars: Metal bars for connecting multiple neutral and earth wires from various circuits.
Cables: Power cables for live (phase), neutral, and protective earth connections.
3. Wiring Steps
Incoming Power:
Connect the three incoming live (phase) cables (e.g., brown, black, grey) to the input side of the main breaker. Connect the incoming neutral (blue) and earth (green/yellow) wires to their respective terminals or busbars.
Outgoing Connections:
Connect the output of the main breaker's phases to the input side of the individual sub-circuit breakers (MCBs or RCBOs) installed on the DIN rail within the DB.
For each sub-circuit, run its live cable to its breaker.
Run the neutral cable from that sub-circuit to a neutral terminal bar.
Run the earth cable from that sub-circuit to the main earth bar.
Cable Dressing:
Neatly arrange and tie the cables together, grouping them by color (e.g., all browns, all blacks/greys, all blues).
Use the appropriate methods to route cables down the back of the spine or around the components without pinching them tightly.
4. Final Checks
Verify connections: Double-check all connections for tightness and correct phasing.
Check cable colors: Ensure you are using the correct, standardized color codes for each conductor type.
Test the system: Once all wiring is complete, you can carefully turn on the main power and test each circuit to ensure it functions correctly and safely. Check Out Our Other Channels :
👉Follow us on Instagram:-
https://www.instagram.com/nselectrica...
👉HOW TO REPAIR IN TAMIL CHANNEL👇
👉 / @howtorepairintamil
👉To Contact NS ELECTRICAL PLUMBINH DIY Channel 👉( ONLY Whatsapp ): 9442699135
Follow us on:
👉❤️ whatsapp Group:https://chat.whatsapp.com/KYzmgt3woxV...
📲 Email: [email protected]
=============================================
....................................................................................
🔥உங்களுக்கு எது போன்ற வீடியோக்கள் வேண்டும் என்பதை கமெண்ட் - ல் குறிப்பிடவும். மேலும் பல விடியோவுக்கு SUBSCRIBEசெய்யுங்கள் நன்றி ..
.................................................................................................................................................................
support me my channel
SUBSCRIBER Thanking for watching
*********************************************************
👨🔧Disclaimer Electrical hazards include exposed energized parts which may become energized unexpectedly (Shock Hazard). If you are unaware of basic electronics with high voltage & transformers, don't do this project. do this project at your own risk. Take safety steps related to electricity. WARNING Copyright disclaimer under section 107 of the copyright Act 1976, allowance is made for "fair use" for purposes HIGH VOLTAGE such as criticism, comment, news reporting, teaching, scholarship, and research. Fair use is a permitted by copytright statute that might otherwise be infringing. Non -profit, educational or personal use tips the balance in favor of fair use.
#nselectricaltechintamil #electrical #plumbing #nselectricalplumbingdiy
👨🔧please don't cry without safety so very dangerous safety your electrician thanks for how to repair in Tamil #NARAYANASAMY