How to Start / Stop and Speed control via HMI in Schneider VFD (Lauritz Knudsen VFD) ?
Автор: EEE BACKBENCHERS
Загружено: 2025-12-09
Просмотров: 148
Описание:
In this video we will you will learn HMI Control i.e. Start /Stop & Speed control from HMI .
and same video is applicable for multiple VFD / Models.
1. Altivar 630.
2. Altivar 930
3. Altivar 610
4. Altivar 910
5. XD4000
6. XD2000
........................................................................................................................
1. How to give Start/ Stop command to Schneider VFD from keypad.
2. How to control speed in Schneider VFD from Keypad.
3. How to use JOG in Schneider VFD from Keypad..
4. How to change Phase Sequence in Schneider VFD.
5. How to set Motor parameter in Schneider VFD.
7. Basic introduction of Schneider VFD .
...........................................................................................................................
1. How to give Start/ Stop command to Lauritz Knudsen from HMI.
2. How to control speed in Lauritz Knudsen VFD from HMI.
3. How to use JOG in Lauritz Knudsen VFD from HMI.
4. How to change phase sequence in Lauritz Knudsen VFD.
5. How to set Motor parameter in Lauritz Knudsen VFD.
7. Basic introduction of Lauritz Knudsen VFD .
..........................................................................................................................
We tried our best to cover all the topics in single video, follow time stamps for direct access of listed topics :-
🕘Timestamps:
0:00 - Introduction
00:36 - Assign Start / Stop
01:53 - RUN Trial
02:38 - Motor Parameters
03:02 - Change Phase Sequence
03:24 - Speed Control
04:00 - Jog / Assign Fix speed
04:33 - Output Relay Setting
06:22 - Thanks
🎬Watch our most recent videos:
▶️ / @eeebackbenchers7966
🎬Schneider VFD : Copy Paste from one drive to another drive:
▶️ • How to copy paste parameters in schneider ...
🎬Schneider VFD 02 source Control ( Push Button & 4-20mA).
▶️ • Schneider Electric VFD(variable frequency ...
🎬Schneider VFD playlist :-
▶️ • Schneider VFD Playlist.
🎬L&T sx2000 vfd speed control from 02 sources (pot-meter & current )|| AO 4-20mA || Motor Parameters
▶️ • L&T sx2000 vfd speed control from 02 sourc...
🎬SX2000: L&T drive parameter setting | Frequency control using UP & Down push button | Fault reset
▶️ • SX2000: L&T drive parameter setting | Freq...
🎬lnt drive AO Calibration and drive to drive AO check
▶️ • LnT VFD(SX2000) Analog Output Calibration ...
To get more updates from follow the below-given link.
🔴Subscribe this Channel - https://www.youtube.com/@eeebackbench...
Press the little bell to get notifications
Watch complete video for all details and Please feel free to give feedback in the comments section about the video.
We appreciate constructive criticism.
#schneider , #lauritzknudsen , #altivar , #vfd , #hmi , #control , #startstop , #speed , #altivar610 , #Altivar910 , #xd4000 , #xd2000 ,#eeebackbencher , #schneiderelectric ,
Thanks.
Повторяем попытку...
Доступные форматы для скачивания:
Скачать видео
-
Информация по загрузке: